COLLAUDI PRESTAZIONALI - SERIE NC 72.1 SUPERTHERMIC

 

PROVE DI TENUTA

 

 

ISTITUTO CERTIFICANTE

 

 

SERRAMENTO

 

 

DIMENSIONI

 

ESITI DEI COLLAUDI

 

E NUMERO

 

B X H

PERMEABILITA' ALL'ARIA

CLASSE

TENUTA ALL'ACQUA

CLASSE

RESISTENZA AL VENTO

CLASSE

IFT

N° 102 31471-9

FINESTRA AD ANTA RIBALTA

1560 X 2060

4

E 900

C4 / B4

IFT

N° 102 31471-10

FINESTRA AD ANTA RIBALTA CON SOTTOLUCE FISSO

1260 X 2240

4

E 900

C4 / B4

IFT

N° 102 31471-11

FINESTRA A DUE ANTE CON AR

2065 X 1860

4

E 900

C4 / B4

IFT

N° 102 31471-12

FINESTRA AD ANTA RIBALTA

1440 X 1740

4

E 1050

C4 / B4

IFT

N° 102 31471-13

FINESTRA AD ANTA RIBALTA CON SOTTOLUCE FISSO

1240 X 2240

4

E 750

C4 / B4

 

 

 

 

PROVA DI CONDUTTANZA TERMICA

 

ISTITUTO

CERTIFICANTE

NUMERO E NORMA

 

ISOLAMENTO TERMICO

IFT. N° 422 29531

EN ISO 10077-2

Uf = 2,5  W/mēK

Uf = 2,4  W/mēK

IFT. N° 422 29531/2

EN ISO 10077-2

Prod.1 Uf = 2,5  W/mēK

Prod.2 Uf = 2,4  W/mēK

IFT. N° 422 29516-2

EN ISO 170077-2

Uf = 4,3  W/mēK

Uf = 2,5  W/mēK

Uf = 2,3  W/mēK

IFT. N° 432 29517-1

EN ISO 170077-2

 

Uf = 2,0 - 2,4  W/mēK

IFT. N° 432 29518-1

EN ISO 170077-2

 

Uf = 2,4 - 2,5  W/mēK

IFT. 402_34971_01

Uf = 2,1  W/mēK - Test in camera calda

IFT. 402_34971_02

Uf = 2,2  W/mēK - Test in camera calda

IFT. 402_34971_03

Uf = 1,9  W/mēK - Test in camera calda

IFT. 402_34971_04

Uf = 2,0  W/mēK - Test in camera calda

 

 

PROVA ACUSTICA

 

ISTITUTO

CERTIFICANTE

 NUMERO E NORME

 

ABBATTIMENTO ACUSTICO

IFT.N°161 21232/1.0.0

DIN 52 210 DIN 4109

dB  50

IFT.N°161 21232/4.0.0

DIN 52 210 DIN 4109

 

dB  50

N.B. I risultati dei collaudi sopra indicati sono stati ottenuti utilizzando profilati, guarnizioni, ed accessori originali METRA.

I procedimenti costruttivi ed applicativi sono quelli indicati nei cataloghi tecnici METRA.